Add New Panasonic WH-SDC0309K3E5/WH-UDZ07KE5 Model to HeatPumpType.md #718

@kamilzierke

Description

@kamilzierke

Add New Panasonic WH-SDC0309K3E5/WH-UDZ07KE5 Model to HeatPumpType.md

Title

Add new Panasonic WH-SDC0309K3E5/WH-UDZ07KE5 model (K-series, 7kW) with updated byte signature

Description

I would like to add a new variant of the Panasonic heat pump model to the HeatPumpType.md database. This model is functionally identical to existing model #56 but has a slightly different byte signature, representing a newer version of the same hardware.

Model Information

  • IDU: WH-SDC0309K3E5
  • ODU: WH-UDZ07KE5
  • KIT: KIT-SDC07KE5
  • Rated Power: 7 kW
  • Series: K-series
  • Refrigerant: R32
  • Type: HP (High Performance)

Byte Signature (bytes 129-138)

The heat pump identification bytes from the protocol are:

E2 D5 0D 08 95 02 D6 10 67 95

Comparison with Existing Model

The closest existing model (ID #56) has the signature:

E2 D5 0B 08 95 02 D6 0F 67 95

Differences:

  • Byte 131: 0D vs 0B (newer version)
  • Byte 136: 10 vs 0F (newer version)

Electrical Configuration

  • Heat Pump Power Supply: 1-phase
  • Internal Heater Power Supply: 1-phase (separate phase)
  • Internal Heater Capacity: 3 kW
  • Total Electrical Configuration: 2-phase setup

This configuration is common in Polish installations where the heat pump runs on one phase and the backup heater on another.

Proposed Addition to HeatPumpType.md

Please add the following entry to the HeatPumpType.md file:

| 57 | E2 D5 0D 08 95 02 D6 10 67 95 | WH-SDC0309K3E5 | WH-UDZ07KE5 | KIT-SDC07KE5 | 7 | 1ph* | HP | *2-phase configuration with 3kW heater on separate phase |

Additional Information

  • User Verification: Confirmed by purchase invoice
  • Operational Status: Successfully decoding all protocol parameters
  • System Status from Logs:
    • Mode: Heating + DHW (byte 6 = 62)
    • Outdoor Temperature: 6°C
    • DHW Current: 41°C / Target: 45°C
    • Compressor Frequency: 47 Hz
    • No errors detected

Testing Data

Developers can use this log fragment for testing (full response available if needed):

71,C8,01,10,56,55,62,49,00,55,00,25,...,E2,D5,0D,08,95,02,D6,10,67,95,...

This model is fully compatible with the existing protocol decoding and only requires addition to the model identification database.

Labels

  • new-model
  • protocol
  • k-series

Thank you for considering this addition to HeishaMon!

Full log

[20:31:21.508][I][panasonic_heatpump:034]: >>> extra_polling_request[111]
[20:31:21.514][I][panasonic_heatpump:047]: >>> 71,6C,01,21,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,
[20:31:21.527][I][panasonic_heatpump:047]: >>> 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,
[20:31:21.545][I][panasonic_heatpump:047]: >>> 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,01

[20:31:21.969][I][panasonic_heatpump:034]: <<< extra_polling_response[203]
[20:31:21.990][I][panasonic_heatpump:047]: <<< 71,C8,01,21,8A,EA,01,00,00,00,00,00,00,00,67,04,01,00,01,00,67,18,01,00,01,00,01,00,00,00,01,00,00,00,01,00,00,00,01,00,
[20:31:22.007][I][panasonic_heatpump:047]: <<< 00,00,01,00,01,00,01,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,
[20:31:22.007][I][panasonic_heatpump:047]: <<< 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,
[20:31:22.017][I][panasonic_heatpump:047]: <<< 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,
[20:31:22.029][I][panasonic_heatpump:047]: <<< 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,
[20:31:22.041][I][panasonic_heatpump:047]: <<< 00,00,3B

[20:31:26.587][I][panasonic_heatpump:034]: >>> polling_request[111]
[20:31:26.587][I][panasonic_heatpump:047]: >>> 71,6C,01,10,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,
[20:31:26.587][I][panasonic_heatpump:047]: >>> 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,
[20:31:26.587][I][panasonic_heatpump:047]: >>> 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,12

[20:31:26.995][I][panasonic_heatpump:034]: <<< polling_response[203]
[20:31:26.996][I][panasonic_heatpump:047]: <<< 71,C8,01,10,56,55,62,49,00,55,00,25,00,00,00,00,00,00,00,00,59,15,11,55,56,1D,55,55,55,19,56,00,00,00,00,00,00,00,83,80,
[20:31:27.012][I][panasonic_heatpump:047]: <<< 80,80,AD,71,71,97,99,00,00,00,00,00,00,00,00,00,00,00,80,85,5B,8A,85,85,D0,7B,78,1F,7E,1F,1F,79,79,8D,8D,9E,94,7B,8F,B7,
[20:31:27.012][I][panasonic_heatpump:047]: <<< A3,7B,8F,94,85,80,8F,8A,94,9E,8F,8A,94,9E,85,8F,8A,04,5B,78,C1,0B,7E,7C,1F,7C,7E,00,00,00,55,55,55,01,11,15,59,05,1C,12,
[20:31:27.021][I][panasonic_heatpump:047]: <<< 65,21,51,15,01,54,80,80,80,E2,D5,0D,08,95,02,D6,10,67,95,9D,00,A9,86,98,9D,32,32,9C,AD,32,32,32,83,9C,9D,BF,96,99,80,00,
[20:31:27.033][I][panasonic_heatpump:047]: <<< 80,00,00,5D,01,19,30,00,00,2F,14,30,5F,37,01,39,01,01,01,AF,00,00,69,01,00,01,00,00,01,00,00,08,01,00,00,00,00,00,00,03,
[20:31:27.046][I][panasonic_heatpump:047]: <<< 80,33,41```

Metadata

Metadata

Assignees

No one assigned

    Labels

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions