Skip to content

Power strip: Fixes calculation of the instantaneous current#50

Merged
rytilahti merged 1 commit intorytilahti:masterfrom
syssi:feature/plug-property-load-power
Sep 3, 2017
Merged

Power strip: Fixes calculation of the instantaneous current#50
rytilahti merged 1 commit intorytilahti:masterfrom
syssi:feature/plug-property-load-power

Conversation

@syssi
Copy link
Copy Markdown
Collaborator

@syssi syssi commented Sep 3, 2017

The value of the property "current" is misleading for countries with 230V mains because it was calculated with a wrong reference voltage (110V). As workaround a calculated property "load_power" is provided now. It's a firmware issue of the Xiaomi strip.

…230V mains because it was calculated with a wrong reference voltage (110V) already.

As workaround a calculated property "load_power" is provided now. It's a firmware issue of the Xiaomi strip.
@rytilahti
Copy link
Copy Markdown
Owner

I trust you on this one too, thanks!

@rytilahti rytilahti merged commit c051211 into rytilahti:master Sep 3, 2017
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment